Guide to Lunar 2021 Modes

Mode 1- Weighing Only

lunar_p9_mode1_01.jpg

In the Weighing Mode, the scale will only display weight, in either grams or ounces.

  • There are two different weighing units in Weighing Mode: gram and ounce.

  • In grams, the LED display shows [ 0.0 ].

  • In ounces, the LED display shows [ 0.000 ] and the Weighing In Ounces Indicator on the

bottom left lights up.
• The readability is 0.1 g or 0.002 oz. For high-resolution mode, the readability is 0.01 g or

0.0005 oz.

 

Mode 2 - Dual Display Mode

lunar_p9_mode2_01.jpg

In the Dual Display Mode, the scale displays [ 0:00 0.0 ] with a timer (left) and weight (right).

There are two different weighing units in Dual Display Mode: gram and ounce. In grams, the LED display shows [ 0:00 0.0 ].
In ounces, the LED display shows [ 0:00 0.000 ].
The timer displays from [ 0:00 ] to [ 9:59 ] and then stops.

• Flow-Rate Indicator is supported in this mode.

 

Mode 3 - Timer Starts with Flow Mode - Droplet

lunar_p10_mode3_00.jpg

When the scale detects the flow of espresso, the timer starts. The timer will stop when the flow stops.

*Please note: The flow detection mode is designed to detect the slow trickle of a shot of espresso. The timer may not trigger when attempting to pour from a kettle.

 

Display

In grams, the LED display shows [ 0:00 0.0 ].
In ounces, the LED display shows [ 0:00 0.000 ]. • Flow-Rate Indicator is supported in this mode.

 

Mode Description

The timer starts when the flow of espresso is detected. When the espresso flow stops, the timer stops.

 

Mode 4 - Auto-Tare Timer Starts with Flow Mode - Droplet and Square

lunar_p11_mode4_00.jpg

This mode is designed for baristas who would like to measure the time of the shot starting from the first few drops of espresso. When the weight reading is stable, the scale will perform the auto-tare operation. After the scale detects the espresso flow, the timer starts automatically. The timer will stop automatically when the espresso flow stops.

 

Display

In grams, the LED display shows [ 0:00 0.0 ].
In ounces, the LED display shows [ 0:00 0.000 ].
The timer displays from [ 0:00 ] to [ 9:59 ] and then stops. • Flow-Rate Indicator is supported in this mode.

Mode Description

• The auto-tare function operates when a stable weight is placed on the scale. • The timer will start automatically when the flow of espresso is detected.

 

Mode 5 - Auto-Tare Auto-Start Timer Mode - Triangle and Square

lunar_p12_mode5_00.jpg

This mode is for baristas to measure the total time of a shot including the pre-infusion time. After a cup is placed on the scale and the weight reading is stable, the scale performs auto-tare and starts the timer.

 

Display

In grams, the LED display shows [ 0:00 0.0 ].
In ounces, the LED display shows [ 0:00 0.000 ].
The timer displays from [ 0:00 ] to [ 9:59 ] and then stops. • Flow-Rate Indicator is supported in this mode.

Mode Description

• The scale performs auto-tare once a stable weight is detected, then the timer starts. • The timer stops when the espresso flow stops.

 

Mode 6 - Auto-Tare Mode - Square

lunar_p13_mode6_00.jpg

In this mode, the scale will only perform auto-tare. Put the cup on the scale and auto-tare will be performed. Pull the shot of espresso as you normally would. When the cup is removed from the scale, the espresso brewing summary will be displayed.

 

Display

• The LED display shows [ 0.0 ] with the weight in grams.
• The LED display shows [ 0.000 ] with the weight in ounces. • Flow-Rate Indicator is supported in this mode.

Mode Description

• The scale performs auto-tare once a stable weight is detected.

 

Mode 7 - Pour Over Auto-Start Timer Mode - Circle and Droplet

 

The Pour Over Auto-Start Timer Mode is designed to aid pour over coffee brewing. The scale will detect the start of the flow from kettle into vessel and automatically start the timer. The timer stops when the brewing equipment has been removed from the scale. When the vessel is removed from the scale, the display flashes the final beverage weight.

 

Display

  • In grams, the LED display shows [ 0:00 0.0 ]
  • In ounces, the LED display shows [ 0:00 0.000 ].
    • Once the timer has started, the LED display shows [ 0:00 0.0 ], with the time elapsed on the left and the weight on the right in grams.
    • Once the timer has started, the LED display shows [ 0:00 0.000 ], with the time elapsed on the left and the weight on the right in ounces.
  • The timer displays from [ 0:00 ] to [ 9:59 ] and then stops.

Mode Description:

  • The timer will start automatically when the first flow of water is detected
  • The timer stops when the brewing equipment is removed. The scale will flash between the beverage weight and the tare weight of the items on the scale.

1. The Circle and Droplet icon indicate that you are in Pour-Over Auto-Start Timer Mode
2. Place a cup on the scale and tare the weight manually.
3. The timer will start automatically when the first flow of water is detected.
4. The timer stops when the brewing equipment is removed. The scale will flash between the beverage weight and the tare weight of the items on the scale.

 

Other Mode Features

Timer Auto Stop

In all three Auto-Start Modes, the timer will stop when the espresso flow stops or when the cup is removed from the scale.

Espresso Brewing Summary

In all Auto Modes (including Auto-Tare Mode), when brewing is complete and the cup is removed from the scale, the display will flash to show the final beverage weight and the average flow rate of the brewing.

Auto-Reset

If the scale remains idle for 30 seconds, it will reset the timer and perform the tare operation. This feature is ideal for streamlining bar workflow. No need to be pressing buttons to reset after lifting the cup from the scale, instead the scale will automatically reset.

 

 

 

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request

Comments

0 comments

Article is closed for comments.

Browse by category